KARVOTECGlobal
Switchgear

Auto-Reclosers

WaveGuard™ — IEEE C37.60-rated reclosers engineered specifically for 60Hz North American distribution networks.

WaveGuard™
IEEE C37.60
ANSI C37.60
IEC 62271-111

Our WaveGuard™ auto-recloser line is purpose-built for North American distribution utilities — 60Hz-rated, IEEE C37.60 type-tested, and engineered for the automatic fault-clearing and service-restoration duty that defines modern feeder protection. This is our most specialized line, developed specifically for the utility distribution automation market rather than adapted from an export-generic design. CSA C22.2 type-test certification for the Canadian market is in progress; current standards compliance is IEEE C37.60 / IEC 62271-111 equivalent.

Rated voltage
15.5 – 38 kV
Rated current
800 / 1200 / 1600 A
Interrupting rating
25 kA (recloser duty) / 31.5 kA (breaker duty)
Short-circuit making capacity
Up to 82 kA peak
Control
PMA controller with NORAD protection & automation system
Operating mechanism
Magnetic actuator (PMA)
Mechanical life
50,000 operations
Frequency
60 Hz (North America)

Request This Solution

Share your ratings and application details — our engineers will confirm fit before quoting.

Submit Inquiry
Start a Conversation

Looking for a trusted engineering partner?

Send us your specification or single-line diagram and our engineering team will respond with a qualified, documented sourcing path.