Auto-Reclosers
WaveGuard™ — IEEE C37.60-rated reclosers engineered specifically for 60Hz North American distribution networks.
Our WaveGuard™ auto-recloser line is purpose-built for North American distribution utilities — 60Hz-rated, IEEE C37.60 type-tested, and engineered for the automatic fault-clearing and service-restoration duty that defines modern feeder protection. This is our most specialized line, developed specifically for the utility distribution automation market rather than adapted from an export-generic design. CSA C22.2 type-test certification for the Canadian market is in progress; current standards compliance is IEEE C37.60 / IEC 62271-111 equivalent.
- Rated voltage
- 15.5 – 38 kV
- Rated current
- 800 / 1200 / 1600 A
- Interrupting rating
- 25 kA (recloser duty) / 31.5 kA (breaker duty)
- Short-circuit making capacity
- Up to 82 kA peak
- Control
- PMA controller with NORAD protection & automation system
- Operating mechanism
- Magnetic actuator (PMA)
- Mechanical life
- 50,000 operations
- Frequency
- 60 Hz (North America)
Request This Solution
Share your ratings and application details — our engineers will confirm fit before quoting.
Submit InquiryLooking for a trusted engineering partner?
Send us your specification or single-line diagram and our engineering team will respond with a qualified, documented sourcing path.